Laboratorio di taratura accreditato di
Manaus – Brazil

Orari

Dom
Closed
Lun
07:45 - 17:00
Mar
07:45 - 17:00
Mer
07:45 - 17:00
Gio
07:45 - 17:00
Ven
07:45 - 17:00
Sat
Closed
Contatti
+55 (92) 3237-7690
Avenida Governador Danilo Mattos de Areosa, 1199
Portaria 4, Bloco J, Setor B
Distrito Industrial I
CEP 69075-351
Manaus/AM

CAPACITÀ DI TARATURA DEL LABORATORIO

Capacità Accreditate
Taratura Riferibile
Electricity
Humidity
Pressure / Vacuum
Temperature
Time / Frequency
Volume
Air Velocity
Scales
Sphygmomanometer legal metrology
Electricity

Electricity

Capacità Accreditate

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

Humidity

Capacità Accreditate

Global Calibration Scope

  • Dew Point sensors ranging -90° C to +95° C
  • RH from 0% – 100%

Common equipment serviced: Dew point sensors, Dew point transmitters, Dew point meters and probes, Hygrometers, Humidity indicators, Moisture meters, Humidity sensors, Humidity loggers, Thermohygrograph, Psychrometers, RH indicators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Capacità Accreditate

Global Calibration Scope

  • Vacuum: primary and secondary
  • Altimeter: up to 47 000 m
  • Pressure gauge: up to 500 MPa

Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

Temperature

Capacità Accreditate

Global Calibration Scope

  • Range: -196°C up to 1550°C
  • Fixed points: TP Ar, TP Mercury, TP Water, Melting point of Galium, FP Indium, FP Tin, FP Zinc, FP Al, FP Ag…

Common equipment serviced: temperature measurers, Generators/calibrators, Chillers, Thermistors, Infrared radiation sources, Temperature Controllers, Temperature Indicators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Capacità Accreditate

Global Calibration Scope

  • Tachometer, stroboscope: 1 up to 600 000 RPM
  • Frequency meters, frequency generators, counters: up to 40 GHz

Common equipment serviced: Digital Timers, Frequency Counters, Frequency Meters / Generators, Frequency Standards, Stopwatches, Stroboscopes, Tachometers, Timers, Phasemeter, Standard RPM generators, Synchro-resolvers, Signal generators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Volume

Volume

Capacità Accreditate

Global Calibration Scope

  • Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
  • Pipette: 0.1µL up to 1 000 mL
  • Syringe: up to 200 mL

Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Air Velocity

Air Velocity

Capacità non accreditate
Scales

Scales

Capacità non accreditate

Global Scope:

  • Non-automatic weighing instruments (NAWI) with maximum capacity up to 240 tons (legal metrology, maintenance and repair)
  • Automatic weighing instruments (AWI) with maximum capacity up to 2000 kg

Common equipment serviced: NAWI, AWI (hopper weighing scales, gravimetric filling instruments, catch weighing scales, dynamic railway weighing, dynamic vehicle weighing, etc.)

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Sphygmomanometer legal metrology

Sphygmomanometer legal metrology

Capacità non accreditate

Global Scope:

  • Leak 0 ≤ F ≤ 200mmHg/min
  • Non-Invasive Blood Pressure 0 ≤ P ≤ 400mmHg
  • Heart Rate 20 ≤ F ≤ 300Bat/min
  • Fast Air Exhaustion 1 ≤ E ≤ 999 s

Common equipment serviced: Sphygmomanometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity
Humidity
Pressure / Vacuum
Temperature
Time / Frequency
Volume
Air Velocity
Scales
Sphygmomanometer legal metrology

Laboratory tour

Our laboratories provides instrument calibration and repair services that are accredited and/or certified in accordance with ISO/IEC 17025. Instrument calibration and repair services can be delivered at your site or at our lab.
Secret Link