ACCREDITAMENTI ISO 17025 E ISO 9001

SCOPE OF ACCREDITATION

CAPACITÀ DI TARATURA DEL LABORATORIO

Capacità Accreditate
Taratura Riferibile
Temperature
Humidity
Density & Viscosity
Temperature

Temperature

Capacità Accreditate

UKAS Calibration Scope

  • Liquid-in-glass thermometers (-80°C to 255°C)
  • Resistance thermometers (-80°C to 255°C)
  • Thermometers with indicators (-80°C to 410°C)
  • Temperature calibration in air (5°C to 50°C)

Common equipment serviced: Dial type temperature indicators, PT100s, Digital Thermometers with sensors, Temperature recorders with sensors, Thermo-Hydrometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

Humidity

Capacità Accreditate

UKAS Calibration Scope

  • 5°C to 20°C (10% rh to 95% rh)
  • 20°C to 25°C (10% rh to 95% rh)
  • 25°C to 50°C (10% rh to 90% rh)

Common equipment serviced: Rh sensors and hand-held humidity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Density & Viscosity

Density & Viscosity

Capacità Accreditate

UKAS Calibration Scope

  • Hydrometers 500 kg/m3 to 2000 kg/m3

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperature

UKAS Calibration Scope

  • Liquid-in-glass thermometers (-80°C to 255°C)
  • Resistance thermometers (-80°C to 255°C)
  • Thermometers with indicators (-80°C to 410°C)
  • Temperature calibration in air (5°C to 50°C)

Common equipment serviced: Dial type temperature indicators, PT100s, Digital Thermometers with sensors, Temperature recorders with sensors, Thermo-Hydrometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Humidity

UKAS Calibration Scope

  • 5°C to 20°C (10% rh to 95% rh)
  • 20°C to 25°C (10% rh to 95% rh)
  • 25°C to 50°C (10% rh to 90% rh)

Common equipment serviced: Rh sensors and hand-held humidity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Density & Viscosity

UKAS Calibration Scope

  • Hydrometers 500 kg/m3 to 2000 kg/m3

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.