Laboratorio di taratura di
Bayonne – France

Orari

Lun
08:00 - 17:00
Mar
08:00 - 17:00
Mer
08:00 - 17:00
Gio
08:00 - 17:00
Ven
08:00 - 17:00
Contatti
+33 (0)5 59 42 33 02
5, rue Joseph Szydlowski
64100 BAYONNE

CAPACITÀ

Capacità Accreditate
Taratura Riferibile
Dimensional
Humidity
Mass / Scale
Pressure / Vacuum
Temperature
Torque
Thermal and climatic testing
Accelerometry
Chemical
Electricity
Force
Gas flow
Dimensional

Dimensional

Capacità non accreditate

Instruments à cotes fixes et à cotes variables, Marbres…
0 à 300 mm sur les cotes fixes
0 à 1 000 mm sur les cotes variables

Humidity

Humidity

Capacità non accreditate

Global Calibration Scope

  • Dew Point sensors ranging -90° C to +95° C
  • RH from 0% – 100%

Common equipment serviced: Dew point sensors, Dew point transmitters, Dew point meters and probes, Hygrometers, Humidity indicators, Moisture meters, Humidity sensors, Humidity loggers, Thermohygrograph, Psychrometers, RH indicators

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Capacità non accreditate

Balances jusqu’à 150 kg

Pressure / Vacuum

Pressure / Vacuum

Capacità non accreditate

Manomètres, Capteurs de pression…
-1 à 100 bar, pression relative

Temperature

Temperature

Capacità non accreditate

Prestations en laboratoire et sur site : Chaînes et capteurs de température, Thermomètres Enregistreurs de Température…
Température : -50 °C à 600 °C

Torque

Torque

Capacità non accreditate

Clé dynamométrique, Tournevis dynamométrique, Visseuse, Couplemètre…
1 à 1 000 N.m

Thermal and climatic testing

Thermal and climatic testing

Capacità non accreditate

Caractérisation de moyens climatiques (étuves, enceintes, fours)…
AMS 2750, FDX 15-140, NFL 06-450
Température de -50 °C à 1 250 °C

Accelerometry

Accelerometry

Capacità non accreditate

Global Calibration Scope

  • Shock: between 20g and 5,000g (subject to device weight and voltage output)
  • Accelerometer: 0.1 m/s² to 750 m/s² (0.4 Hz to 10 kHz…)

Common equipment serviced: Integrated piezoelectric electronics, Piezoelectric accelerometers, Piezoresistive accelerometers, Charge amplifiers and systems

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Chemical

Chemical

Capacità non accreditate

Global Calibration Scope

  • Viscosity: kinematic and dynamic, consistometric cup, etc.
  • Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
  • Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
  • Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.

Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Electricity

Capacità non accreditate

Global Calibration Scope

  • AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
  • High voltage:
    • DC: 1 kV to 200 kV
    • AC (50 Hz): 1 kV to 175 kV
  • Magnetometers: 0 to 1700 mT…

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Force

Force

Capacità non accreditate

Global Calibration Scope

  • Push pull force measuring devices in tension and compression: up to 1 MN
  • Force machine: up to 5 MN (compression) and up to 1 MN (tension)

Common equipment serviced: Dynamometers, Force machines (Tension and/or Compression), Load cell, Force gauges, Strainmeter, Crimping pliers, Charpy testers, Cable tie tools, Press, Retention tools, Wire wrap tools, Spring balance

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Gas flow

Gas flow

Capacità non accreditate

Global Calibration Scope: Gas flow (air): 0.5 ml/min to 4000 m3/h (the range is lower depending on gas used (nitrogen, argon or any inert gases)

Common equipment serviced: Anemometers (thermal & vane), Bubble flowmeters, Gas flow meters, Gas meters, Thermal mass flow controllers, Variable area flow meters, Backflow gages, Flow analyzers, Gas flow meters, Flow transducers, Flow transmitters, Leak testers, Orifices, Rotameters, Turbine meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Instruments à cotes fixes et à cotes variables, Marbres…
0 à 300 mm sur les cotes fixes
0 à 1 000 mm sur les cotes variables

Humidity
Mass / Scale

Balances jusqu’à 150 kg

Pressure / Vacuum

Manomètres, Capteurs de pression…
-1 à 100 bar, pression relative

Temperature

Prestations en laboratoire et sur site : Chaînes et capteurs de température, Thermomètres Enregistreurs de Température…
Température : -50 °C à 600 °C

Torque

Clé dynamométrique, Tournevis dynamométrique, Visseuse, Couplemètre…
1 à 1 000 N.m

Thermal and climatic testing

Caractérisation de moyens climatiques (étuves, enceintes, fours)…
AMS 2750, FDX 15-140, NFL 06-450
Température de -50 °C à 1 250 °C

Accelerometry
Chemical
Electricity
Force
Gas flow

Laboratory tour

Our laboratories provides instrument calibration and repair services that are accredited and/or certified in accordance with ISO/IEC 17025. Instrument calibration and repair services can be delivered at your site or at our lab.
Secret Link